Table 10: Power consumption
Power Consumption
in
E-GSM 900/DCS 1800 MHz - GPRS class 10
E-GSM 900 DCS 1800
Input Peak Supply Current
During 2TX bursts @Pcl5
@ 5.5 V
1500 mA
(average)
1420 mA
(average)
Input average supply current in
communication mode
Average 3Rx/2Tx @Pcl5
@ 5.5 V 341 mA RMS 324 mA RMS
Input Peak Supply Current
During 1TX bursts @Pcl5
@ 5.5 V
1780 mA
(average)
1670 mA
(average)
Input average supply current in
communication mode
Average 1Rx/1Tx @Pcl5
@ 5.5 V 200 mA RMS 189 mA RMS
Input average supply current in
idle mode with no RS232 link
@ 5.5 V 14 mA 14 mA
Input average supply current in
idle mode with active RS232 link
@ 5.5 V 31 mA 31 mA
Input average supply current in
idle mode with autoshutdown
@ 5.5 V 14 mA 14 mA
The power consumption might vary by 5 % over the whole operating
temperature range (-20 °C to +55 °C).