*Optional
Note: When using 3-Phase adaptors the NCNT function will need to be over ridden by pressing the ‘OKkey
prior to the TnP appliance tester performing the assigned test. Some single Phase appliances controlled by
contactors will also require manual over ride. In some instances holding the ‘ON’ button will enable the NCNT
function to work normally.
Visual Inspection (First Test)
VISUAL INSPECTION IS TO OCCUR BEFORE ANY OTHER TEST IS CARRIED OUT BEFORE USING ANY
OF THE RANGE OF TnP APPLIANCE TESTERS
There is no damage or component defects to the accessories, plugs, outlet sockets or connectors
(physical).
There are no cracks &/or abrasions.
There are no exposed inner cores or conductors (flexible) and the supply cords are not twisted or
distorted.
Any Fuse / Over load protection components (if fitted) are checked.
All labels, markings and warning indicators (of the maximum load to be connected to the device) are
legible and intact.
The insulation is not damaged in any way i.e. melted, cuts or abrasions. There are no iron filings in the
insulation. There is no insulation tape on the lead.
Any flexible cords and/or leads are effectively anchored (glands and grommets intact).
All covers or guards are in place and secure as intended by the supplier/manufacturer.
All safety devices and systems are in good working order. (i.e. overload latches & buttons).
No dust &/or dirt obstructs any exhausts or ventilation outlets.
All controls are working properly and are secure and aligned.
Important: If result is a FAIL!!
If any Equipment FAILS ANY of the above, it should be deemed to have FAILED the Visual Test, and therefore
no other tests need be performed. If this is the case the Equipment should be tagged with a DANGER TAG and
removed from service. It is recommended by the manufacturer and distributor of this product that it SHOULD
NOT BE RETURNED TO SERVICE. To do so would be considered unsafe.
Fully Integrated Test n Print Unit
TnP-500 & TnP-500X
Introduction to Memory functions
The TnP units have Memory. There is inbuilt flash memory and a real time clock. This gives the ability to store
up to 5,000 records, which can include items from 16 different sites and 6 different users. This will help to
increase the efficiency and pace of testing. The TnP units (with memory) have two operating modes:
TnP tester mode only, no devices attached
Test and Tag mode, all devices connected & on, allowing testing,scanning, retrieval & printing
The TnT mode is determined if a keyboard is connected. If there is no keypad detected then the TnP will load
the main menu screen and function as a standard unit. If the keypad is present then the new barcode screen will